Victron Energy® BPR000220400 - 12V/24V 220A Battery Protect

0 reviews|Item # mpn4672091453|Similar Products
Authorized Dealer
$101.75
OUT OF STOCK - Unavailable until further notice
Authorized Dealer
Have a Question? Ask a Specialist
888-453-5141Live Chat

Product Details

12V/24V 220A Battery Protect (BPR000220400) by Victron Energy®. The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

Notes

  • The BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual
  • The BatteryProtect is not designed for reverse currents from charging sources

Specifications

Voltage: 12V/24V
Amperage: 220A
Dimensions (mm): 120 L x 123 W x 63 H

Features

  • Engineered with innovative technologies
  • Designed with functionality in mind
  • Fusion of modern-day technology and first-rate quality

Installation

12/24V auto ranging The BatteryProtect automatically detects system voltage
Programming made easy The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen.
A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS.
Ultra low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see Victron Energy Li-ion battery datasheet and the VE.Bus BMS manual for more information.
Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.
Ignition proof No relays but MOSFET switches, and therefore no sparks.
Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

Victron Energy® products include sinewave inverters, sinewave inverters/chargers, battery chargers, DC/DC converters, transfer switches, battery monitors and more. Victron Energy has a strong, unrivalled reputation for technical innovation, reliability, and build quality. Victron Energy products are widely considered to be the professional choice for independent electric power.

Part Number:
BPR000220400

Reviews

(0)
Only authorized customers can leave a review on our website. We would love to know what you like or dislike about the product. Share your opinion on product quality, appearance, installation, and other characteristics.
Victron Energy® BPR000220400 - 12V/24V 220A Battery Protect
/0

Questions and Answers

(0)
If you have any questions about this product, please don't hesitate to ask us. We will be happy to help you!